F. Imeri Sàrl
2829 Vermes · about 26 km
The website presented under the name Imeri Chauffage et Sanitaire Sàrl offers plumbing, heating and solar thermal work, while F. Imeri Sàrl’s registered purpose refers to a scrap metal business.
imeri-sarl.chHeat pump installation · Langenthal

At a glance
Small project
CHF 31'500 – CHF 57'500
Typical project
CHF 39'700 – CHF 74'000
Large project
CHF 52'100 – CHF 98'600
| Project | Quantity | Low | High | Per unit |
|---|---|---|---|---|
| Small project | 80 m² | CHF 31'500 | CHF 57'500 | CHF 500 |
| Typical project | 160 m² | CHF 39'700 | CHF 74'000 | CHF 300 |
| Large project | 280 m² | CHF 52'100 | CHF 98'600 | CHF 300 |
Computed with our estimator for Langenthal (regional factor included), standard finish. Only the project size changes.
Included
Not included
In Langenthal, the federal building register lists 3'011 residential buildings and 8'072 dwellings. These municipal benchmarks help put your home in context, but do not replace an individual assessment.
69 % built before 1980
Construction year does not reveal past renovations: check the current insulation condition.
51 % · Gas
This distribution describes recorded buildings, not your system's consumption or efficiency.
| Energy | Heating | Hot water |
|---|---|---|
| Gas | 51 % | 45.4 % |
| Heating oil | 18 % | 14.3 % |
| District heating | 1 % | 0.6 % |
| Heat pump | 21 % | 12.8 % |
| Electricity | 2 % | 21 % |
| Wood | 7 % | 2.8 % |
| Solar thermal | 0 % | 1 % |
Each line gives the share of buildings using that energy, separately for heating and for hot water. The two columns do not always reach 100%: some buildings combine two systems, or reported none.
A standard non-condensing boiler is usually older and less efficient.
For renovation planning in Langenthal, official building register figures provide essential insights. With 8 buildings classified under heritage protection out of 223 known, early consultation with local authorities is vital regarding permit requirements. Regarding building volume, the median is 877 m3 based on the SIA 416 standard; however, this reflects only 37 houses out of 1904, indicating partial data coverage. Understanding these metrics helps homeowners accurately scope insulation and heating upgrades. Use these indicators as a foundation for your renovation strategy, while noting that official heritage status dictates the specific constraints applied to your property improvements.
Source : OFS — RegBL (export communal complet). Existing residential buildings; percentages of recorded values.
First check whether your area can connect to a priority district heating network. If a network solution is available, it may be more suitable than an individual heat pump.
If you choose a heat pump, the local design outdoor temperature determines the capacity needed to heat your building efficiently. A rigorous thermal analysis helps avoid oversized systems, ensuring better seasonal performance.
Consult our experts via RenoIndex to evaluate the feasibility of your project according to the geographical configuration of your home in the Langenthal area.
When planning in Langenthal, ensure the outdoor unit is placed away from rest areas, such as bedrooms, and prioritize low-noise models. The use of acoustic barriers or covers can also mitigate noise.
RenoIndex helps you integrate these technical parameters right from the cost estimation phase of your future installation.
Replacing a fossil fuel boiler with a heat pump offers significant advantages for increasing the value of your home. However, to ensure optimal performance, insulating your thermal envelope remains essential.
In the canton of BE, it is recommended to optimize roof and facade insulation before installing a heat pump. A well-insulated building allows the pump to operate at a lower power setting, saving energy and extending the compressor's lifespan.
Our RenoIndex estimator helps you calculate potential costs for these supplementary works for a successful energy transition.
Realizing a heating project requires rigorous planning to avoid financial surprises. In addition to purchasing the machine, do not forget to include connection fees, boiler room modifications, and labour costs.
An accurate initial quote is essential to avoid any surprises. With RenoIndex, quickly obtain a reliable price range for your heat pump project in Langenthal.
This process allows you to compare quotes from different installers with full knowledge and validate your budget before commencing the transformation work on your heating system.
1. Estimate
Set a budget range with the estimator.
2. Grants
Apply before work starts.
3. Quotes
Compare at least 3 quotes.
4. Permit
Check with the municipality whether a permit is needed.
5. Works
Follow the site and do a written handover.
No specific grant listed for this work. Maintenance tax deductions may still apply.
2829 Vermes · about 26 km
The website presented under the name Imeri Chauffage et Sanitaire Sàrl offers plumbing, heating and solar thermal work, while F. Imeri Sàrl’s registered purpose refers to a scrap metal business.
imeri-sarl.ch2832 Rebeuvelier · about 30.7 km
Eco6therm specializes in the installation of heating systems, particularly heat pumps, and solar photovoltaic energy solutions.
eco6therm.ch2824 Vicques · about 31.6 km
Specialist since 1968 in sanitary installations, heating (gas, oil, wood, renewable energy), and tinsmithing with 24/7 emergency repair service.
sanit.ch2824 Vicques · about 31.6 km
Buchwalder Sàrl in Vicques has specialized in the installation, repair, and renovation of heating and sanitary systems since 1966.
buchwalder-sarl.chSuggestions from the commercial register by distance and activity. Not an endorsement or partnership.
Use the free RenoIndex estimator to get a realistic price range based on your building type and the technical solution being considered. This will allow you to better budget your project before requesting detailed quotes from local professionals.
Air-water heat pumps must meet strict noise limits towards neighbours to avoid disturbance. It is advisable to carefully choose the location of the outdoor unit and check current standards before final installation.
Yes, good thermal insulation is recommended. It allows the heat pump to operate more efficiently, reduces the required power capacity, and lowers your electricity bills in the long term while increasing thermal comfort.
Yes, always check whether your area can connect to a priority district heating network. If this option is available, it may be a simpler and more efficient alternative to installing an individual heat pump.