Hallenbarter & Russi Gebäudetechnik AG
3988 Obergoms · about 80.8 km
Obergoms-based company specializing in sanitary installations, heating systems, roofing, and tinsmith work for new builds and renovations.
hallenbarter-russi.chHeat pump installation · Baar

At a glance
Small project
CHF 29'100 – CHF 53'200
Typical project
CHF 36'700 – CHF 68'300
Large project
CHF 48'100 – CHF 91'100
| Project | Quantity | Low | High | Per unit |
|---|---|---|---|---|
| Small project | 80 m² | CHF 29'100 | CHF 53'200 | CHF 500 |
| Typical project | 160 m² | CHF 36'700 | CHF 68'300 | CHF 300 |
| Large project | 280 m² | CHF 48'100 | CHF 91'100 | CHF 200 |
Computed with our estimator for Baar (regional factor included), standard finish. Only the project size changes.
Included
Not included
In Baar, the federal building register lists 2'570 residential buildings and 11'662 dwellings. These municipal benchmarks help put your home in context, but do not replace an individual assessment.
49 % built before 1980
Construction year does not reveal past renovations: check the current insulation condition.
41 % · Heating oil
This distribution describes recorded buildings, not your system's consumption or efficiency.
| Energy | Heating | Hot water |
|---|---|---|
| Gas | 28 % | 20.8 % |
| Heating oil | 41 % | 35.6 % |
| District heating | 1 % | 0.4 % |
| Heat pump | 21 % | 10.3 % |
| Electricity | 3 % | 26.1 % |
| Wood | 6 % | 4 % |
| Solar thermal | 0 % | 2.3 % |
Each line gives the share of buildings using that energy, separately for heating and for hot water. The two columns do not always reach 100%: some buildings combine two systems, or reported none.
A standard non-condensing boiler is usually older and less efficient.
For renovation projects in Baar, the official building register provides essential insights. Regarding heritage protection, 808 buildings are classified as protected out of 939 known cases, making early consultation with municipal authorities vital for your permit process. The median house volume is 1719 m3, which helps determine the scale for heating and insulation upgrades. Please be aware that these volume figures are based on only 10 units measured via the SIA 416 standard. Consequently, the data coverage is partial, and homeowners should consider these limitations when planning renovation budgets or assessing technical requirements for their specific property.
Source : OFS — RegBL (export communal complet). Existing residential buildings; percentages of recorded values.
Before taking technical steps, first check whether your area can connect to a priority district heating network. Once you have clarified this, calculating the required capacity for your heat pump is essential.
The local design outdoor temperature sets the heat pump's capacity needed to ensure your comfort during harsh winters. It is recommended to perform a complete energy audit of your building to properly size the unit.
Do not forget to use the free RenoIndex estimator to obtain a cost range and structure your budget before contacting professionals for detailed quotes.
When installing an air-water heat pump outdoors, acoustic management is a central aspect of the project. Outdoor air-water heat pumps must meet noise limits towards neighbours to prevent any disputes.
It is recommended to position the outdoor unit at a sufficient distance from rest areas, such as bedrooms, or to use noise barriers if space is limited.
Careful planning ensures compliance with standards and maintains harmonious relations with your neighbours. Check out RenoIndex for more technical tips on the ideal location and to get a comprehensive price estimate for your installation.
The efficiency of a heat pump depends heavily on your building's insulation quality. Before switching systems, consider checking your windows and roof integrity. Enhanced insulation reduces the capacity required and lowers initial investment costs.
By selecting high-performance equipment adapted to your local setup in the canton of Zug, you maximize long-term energy savings.
Use the RenoIndex tool to compare costs for different solutions and find the best balance between initial investment and overall energy efficiency for your home in Baar.
Budgeting is a key step in any energy renovation project. While the initial cost might seem high, it is essential to consider the operational savings generated by an efficient heat pump.
For your project in Baar, ensure you factor in all secondary costs such as electrical connections or necessary outdoor landscaping. RenoIndex provides valuable transparency by offering a current price range for the market.
Do not hesitate to use this free tool to refine your budget and better anticipate the expenses related to your energy transition.
1. Estimate
Set a budget range with the estimator.
2. Grants
Apply before work starts.
3. Quotes
Compare at least 3 quotes.
4. Permit
Check with the municipality whether a permit is needed.
5. Works
Follow the site and do a written handover.
No specific grant listed for this work. Maintenance tax deductions may still apply.
3988 Obergoms · about 80.8 km
Obergoms-based company specializing in sanitary installations, heating systems, roofing, and tinsmith work for new builds and renovations.
hallenbarter-russi.ch2829 Vermes · about 81.5 km
The website presented under the name Imeri Chauffage et Sanitaire Sàrl offers plumbing, heating and solar thermal work, while F. Imeri Sàrl’s registered purpose refers to a scrap metal business.
imeri-sarl.ch2824 Vicques · about 86.4 km
Specialist since 1968 in sanitary installations, heating (gas, oil, wood, renewable energy), and tinsmithing with 24/7 emergency repair service.
sanit.ch2824 Vicques · about 86.4 km
Buchwalder Sàrl in Vicques has specialized in the installation, repair, and renovation of heating and sanitary systems since 1966.
buchwalder-sarl.chSuggestions from the commercial register by distance and activity. Not an endorsement or partnership.
First, check whether your area can connect to a priority district heating network. If this is not possible, you can proceed with planning an individual heat pump solution.
The local design outdoor temperature is crucial. It defines the minimum power the pump must be able to provide to maintain your comfort during the coldest days.
Outdoor air-water heat pumps must meet strict noise limits towards neighbours. Careful positioning and the use of noise barriers can significantly reduce noise levels.
Use the RenoIndex estimator to get a price range tailored to your situation. It is a free tool that helps you prepare your budget before contacting professionals.